The CDS-9022 has led DataRemote’s product line for nearly 15 years. This rugged, UL-listed unit works on any CDMA, PCS or analog network. The device is remotely programmable and is able to make outbound data and voice calls to three
pre-programmed phone numbers. The CDS-9022 is currently used throughout North and South America by large utility
companies and DOTs to monitor and program remote equipment.
|
|
| |
| |
- AT command SMS send/receive (AT+CMGS)
- Update PRL while unit is in the field
- Configuration menu remotely or locally programmable
- Inputs for cry-out alarms
- Call processing: CDMA digital 800MHz, CDMA PCS 1900 MHz, optional analog circuit-switch fall back
- Connects to RTUs, PLCs, Dataloggers, etc. through a terminal block or DB-9 RS232 (optional RS-485)
- UL listed – Class 1, Division 2, Group A, B, C and D Hazardous
- More than just a modem – outbound data calls (SMS via AT commands or triggered by inputs/outputs)
- Fall back to circuit-switch analog data when digital coverage unavailable
- Remote programming
- Optional TCP/PPP internal stack
- Power-saving sleep windows for low power applications
|
| |
Typical Applications
Automatic Meter Reading (AMR), Remote Point of Sale (POS), Wireless Telemetry, SCADA, Video Monitoring, Traffic
Sensor Monitoring, Alarm & Equipment Monitoring, Automatic Teller Machines (ATM), Short Message Service (SMS),
Automatic Vehicle Location (AVL)
|
| |
| |
| |
| General Specifications |
| Power Requirements: |
8-32VDC @ 2A (unregulated) |
|
| On-Board Backup: |
3.6V 200MA (CR2032) Lithium Cell |
|
| Serial I/O: |
1 DB-9 RS-232 Async and 8 pos. terminal block |
| Control I/O: |
12 pos. IDC header, 6 inputs/6 outputs (send cry-out alarms via SMS to your cell phone) |
| Command Protocol: |
AT Command Set and DataRemote, Inc. (DRiP) configuration menu |
| LED Indicators: |
Power ON, Signal Status, TXD, RXD, DCD, DTR |
| CDMA Modem: |
IS-707A; IS-95A/B - MDR verified |
|
| Optional: |
AMPS modem (Conexant chipset 300bps to 33.6bps) |
| Vocorder: |
8 Kbps CELP, 13 Kbps QCELP, 8 Kbps EVRC |
| |
|
|
| RF Specifications |
800 MHz |
1900 MHz (CDMA) |
| Interface Standards: |
AMPS: ANSI/TIA/EAI-553 |
J-STD-008 |
| |
CDMA: TIA/EIA, IS-95A/B |
|
| Operating Frequencies: |
TX: 824-849 MHz |
TX: 1850-1910 MHz |
| |
RX: 869-894 MHz |
RX: 1930-1990 MHz |
| RF Power: |
AMPS: 600mW (EIRP Nom.) |
200mW (EIRP Nom.) |
| |
CDMA: 200mW (EIRP Nom.) |
|
| Maximum TX Power: |
AMPS: +26.7dBm Min. +23dBm Min. |
|
| |
CDMA: +23dBm Min. |
|
| Receiver Sensitivity: |
AMPS: >116dBm @ 12dB Sinad |
>104 dBm @ .05% FER |
| |
CDMA: >-104dBm @ 0.5% FER |
|
| Frequency Stability: |
< ± 2.5 PPM |
< ± 2.5 PPM |
| Antenna Interface: |
50 ohm, TNC |
50 ohm, TNC |
| Current: |
Normal current draw = 53ma in Idle Mode (can vary from network to network) |
| |
|
|
| Physical Specifications |
|
|
| Size: |
6.5"L X 3.7"W X 2.5" H |
|
| Weight: |
24.0 Oz. |
|
| |
|
|
| Environmental Specifications |
|
|
| Temperature: |
Operating: -30° C to +60° C |
|
| |
Storage: -40° C to +70° C |
|
| Humidity: |
0-95% (non-condensing) |
|
| |
|
|
| View the printer-friendly PDF copy of the product specificaitons |
|